EasyManua.ls Logo

CAME RSE - Master Barrier Electrical Connections; Command Input Functions

CAME RSE
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
11
2
3
1
2
2
3P
2
4
2
7
ITALIANO - ENGLISH - ESPAÑOL
ITALIANO - ENGLISH - ESPAÑOL
Pulsante (N.C.) arresta entrambe le barriere
Pushbutton (N.C.) stops both the barriers
Botón (N.C. ) detiene ambas barreras
Pulsante (N.O.) apre solo la barriera MASTER
Pushbutton (N.O.) opens the MASTER barrier only
Botón (N.A. ) abre sólo la barrera MASTER.
Pulsante (N.O.) apre solo la barriera SLAVE
Pushbutton (N.O.) opens the SLAVE barrier only
Botón (N.A. ) abre sólo la barrera MASTER.
Pulsante (N.O.) chiude solo la barriera MASTER
Pushbutton (N.O.) closes the MASTER barrier only
Botón (N.A. ) cierra sólo la barrera MASTER.
Pulsante (N.O.) chiude solo la barriera SLAVE
Pushbutton (N.O.) closes the SLAVE barrier only
Botón (N.A. ) cierra sólo la barrera SLAVE.
COLLEGAMENTI ELETTRICI / ELECTRICAL CONNECTIONS / CONEXIONES ELÊCTRICAS
I dispositivi di comando collegati ai
morsetti della scheda elettronica della
barriera MASTER hanno le seguenti
funzioni:
N.B. Per la funzione di chiusura
automatica attivare dip swicth 1 ON
su entrambe le barriere.
The command devices connected to
terminals of the MASTER barrier’s
electronic board have the following
functions:
N.B. To activate the automatic-closing
function, set dip switch 1 to ON for both
the barriers.
Los dispositivos de mando
conectados a los bornes de la tarjeta
electrónica de la barrera MASTER
tienen las siguientes funciones:
N.B. Para la función de cierre
automático active el dip swicth 1 ON
en ambas barreras.