Connects the 230V AC power supply to terminals L and N for operation.
Provides 24V AC/DC for accessories, with a maximum total power allowance of 40W.
Connects a flashing light with a contact capacity of 24V and a maximum of 25W.
Connects the 24V DC gearmotor to the control board terminals.
Connects the encoder for receiving motor position feedback signals.
Connects a normally closed (N.C.) stop button for safety interruption.
Connects normally open (N.O.) devices for activating partial opening sequences.
Connects a normally closed (N.C.) contact for reopening the gate during closing.
Connects normally open (N.O.) devices for controlling opening and closing operations.
Connects the antenna for radio frequency reception and remote control.
Adjusts amperometric sensitivity for slowdown phases, affecting motor direction on force detection.
Sets waiting time in open position before auto-closing; minimum excludes this function.
Adjusts amperometric sensitivity during closing, affecting motor direction on force detection.
Adjusts amperometric sensitivity during opening, impacting motor direction on force detection.
Activates procedures for adjusting opening/closing endpoints and programming decelerated opening.
Activates procedures for partial opening and programming decelerated closing endpoint.
Connects the antenna and radiofrequency card after powering off the control board.
Warning: System supports memorizing up to a maximum of 24 unique transmitter codes.
Memorizes transmitters for sequential command via ENC/RADIO and transmitter button.
Memorizes transmitters for partial opening using ENC/RADIO and OP/CL buttons.
Deletes all stored radio transmitters by setting DIP switches and pressing ENC/RADIO.
Sets the closing end-stop using dip-switch 1, AP/CH switch, and ENC/RADIO button.
Sets the opening end-stop using OPEN button, ENC/RADIO button, and dip switch 1.
Tests programmed end-stops by initiating opening and closing cycles with AP/CH button.
Sets partial opening by using DIP switch 2, OPEN button, and ENC/RADIO button.
Programs decelerated opening by adjusting A.C.T. trimmer and using DIP switch 1, ENC/RADIO, and OP/CL buttons.
Programs closing deceleration by using DIP switch 2, ENC/RADIO, and OPEN buttons.
Product and packaging are recyclable; investigate local disposal systems and regulations.
Caution: Some electronic components may contain polluting substances; avoid littering.