General IconGeneral
Max. motor power800 W
Power supply230V AC ±10%, 50/60Hz
Operating temperature-20 ÷ +55 °C
Operating Voltage230V AC ±10%, 50/60Hz
Power Consumption800W

Summary

Electrical Connections

Power Supply and Motor Connections

Details main power input, motor terminals, and accessory power outputs.

Safety and Command Inputs

Covers connections for stop buttons, keyswitches, and safety devices like photocells.

Indicator and Receiver Connections

Explains connections for gate indicator lights and radio receivers.

Limit Switches

Details connections for FA-F (open) and FC-F (close) limit switches.

Remote Control Operation

Activating Remote Control

Steps for connecting antenna and installing radiofrequency card.

Button Memorisation

Process for memorising CH1 and CH2 buttons on the transmitter.

Programming Decelerations

Deceleration Setup Procedure

Step-by-step guide to program gate deceleration endpoints.

Adjusting Deceleration Speed

How to modify deceleration speed using CH1 and CH2 buttons.

Excluding Decelerations

Method to disable deceleration using DIP Switch 10.

Modifying Re-closing Partial Stop

Partial Stop Configuration

Steps to activate and modify the re-closing partial stop function.

Adjustment Trimmers

Trimmer ACT: Waiting Time

Sets the waiting time while the gate is open before automatic closing.

Trimmer PAR.OP.: Partial Opening

Sets the duration of the gate's partial opening.

Function Selector E (DIP Switches)

Basic Operation Modes

DIP switches 1-4 control closing modes, open/stop, open-close, and open only functions.

Safety and Indicator Functions

DIP switches 5-8 manage flasher, obstacle detection, and specific safety behaviors.

Stop and Slowing Functions

DIP switches 9-10 control total stop and limit switch slowing activation.

Function Selector F (DIP Switches)

Command Mode Selection

DIP switches 1-2 select command modes like closing only, open-close, or opening.

Reader and Disconnected States

DIP switches 3-4 configure the optical reader and disconnected states.

Product Disposal

Environmental Disposal Guidelines

Information on recycling and proper disposal of the product and packaging.