1 ON - Closing only – with command device connected on contact 2-7 (1 OFF – deactivated)
1 OFF - Open-close – with command device connected on 2-7 (see 10-way Dip Switch 2 of the function selector) (1 ON – deactivated).
2 ON - Only opening – with command device connected on contact 2-3P (2 OFF – deactivated).
2 OFF - Partial opening – with command device connected on contact 2-3P (2 ON – deactivated).
3 ON - Optical reader deactivated; (3 OFF –activated); to program deceleration you need to activated the optical reader.
4 ON - disconnected
NOTE: make selections when motor is stopped and in the closed position.