FIGURE 5-3. Module with public static IP address
FIGURE 5-4. Module with private dynamic IP address
5.1 Modules using Konect PakBus Router
(private dynamic IP)
5.1.1 Configure RV50(X)
1. Download the collection of RV50(X) configuration templates from
www.campbellsci.com/downloads and run the executable downloaded.
2. Connect the Cellular antenna.
3. Connect the Diversity antenna, if used. Recommended but not required. Note: If a Diversity
antenna is not used, use ACEmanager to disable WAN/Cellular > Network Credentials >
RX Diversity.
4. Connect the power cable leads to a power supply.
Wire Color Function Connect To
Black Ground G
White Enable (On/Off) 12V or SW12V or control port
Red Power (7 to 36 V) 12V
5. Connect the power cable to the RV50(X) DC Power input. When the RV50(X) is properly set
up and powered, the status LEDs will turn on. The RV50(X) will begin the
activation/provisioning process and attempt to connect to the mobile network. This process
typically takes 5 to 10 minutes. A successful connection is indicated by a solid green or solid
amber Network LED.
RV50(X) Sierra Wireless AirLink® 4G LTE Cellular Modem 10