10. Click the Template button in the ACEmanager toolbar. A template application window will
appear. Browse to and upload one of the configuration templates downloaded from
Campbell Scientific.
Template Files
Template File Name Description
RV50_115200.xml
Default configuration with RS-232 at 115200 baud and
Ethernet communication enabled.
1
RV50_9600.xml
Default configuration with RS-232 at 9600 baud and
Ethernet communication enabled.
2
1
CR1000X series, CR300 series, CR6 series, CR1000, CR3000, CR800 series, CR5000, and GRANITE 6/9/10
2
CR10X, CR10X-PB, CR510, CR510-PB, CR23X, CR23X-PB, and CR200(X) series data loggers
11. Reboot the RV50(X) after successfully applying the configuration template. You can do this
by clicking the Reboot button on the ACEmanager toolbar, by momentarily pressing the
Reset button (2 sec), or by temporarily removing power from the RV50(X).
5.1.2 Enabling PPP mode
Launch the Device Configuration Utility . All tabs are within the Deployment category.
On the Datalogger tab, change the data logger PakBus Address and optional PakBus/TCP
Password to match the values entered in the Set up Konect PakBus Router (p. 6) step.
RV50(X) Sierra Wireless AirLink® 4G LTE Cellular Modem 12