module using the serial cable supplied with the SC105. The SC105 is attached to the data logger
CS I/O port using the SC12 cable supplied with the SC105.
7.3.2 Module power connections
Connect the power cable leads to a power supply.
Wire Color Function Connect To
Black Ground G
White Enable (On/Off) 12V or SW12V or control port
Red Power (7 to 36 V) 12V
Connect the power cable to the RV50(X) DC Power input. When the RV50(X) is properly set up
and powered, the status LEDs will turn on. The RV50(X) will begin the activation/provisioning
process and attempt to connect to the mobile network. This process typically takes 5 to 10
minutes. A successful connection is indicated by a solid green or solid amber Network LED.
Controlling power to the RV50(X) (p. 43) provides an example CRBasic program using the SW12
() instruction.
The USB port provides power for module configuration, but is not sufficient for normal
operation.
7.3.3 Antenna connections
Connect the antennas to the Cellular and Diversity SMA antenna connectors.
FIGURE 7-1. Antenna connections
1. Connect the cellular antenna to the Cellular antenna connector. Mount the cellular
antenna so there is at least 20 cm between the antenna and the user or any bystander.
2. Connect a second antenna to the Diversity antenna connector.
RV50(X) Sierra Wireless AirLink® 4G LTE Cellular Modem 31