11. Reboot the RV50(X) after successfully applying the configuration template. You can do this
by clicking the Reboot button on the ACEmanager toolbar, by momentarily pressing the
Reset button (2 sec), or by temporarily removing power from the RV50(X).
5.2.2 Enabling PPP mode
Launch the Device Configuration Utility . All tabs are within the Deployment category.
On the Datalogger tab, make note of the data logger PakBus Address (default address is 1).
On the Com Ports Settings tab, select the COMPort where the module is connected; this is
generally RS-232. Change the Baud Rate to 115200 Fixed.
RV50(X) Sierra Wireless AirLink® 4G LTE Cellular Modem 20