7.1 Base station requirements
A computer running Campbell Scientific LoggerNet software with access to the Internet is
needed.
7.2 Data logger site equipment
l RV50(X) module with power cable (included with module)
l Data logger — CR1000X series, CR300 series, CR6 series, CR1000, CR3000, CR800 series,
CR5000, and GRANITE 6/9/10
l Module Interface, see Module communications connections (p. 30)
l Environmental Enclosure — ENC10/12, ENC12/14, or ENC16/18
If connecting to CS I/O port:
SC105 Interface — connects the module to any data logger with a CS I/O port. It must
be configured using Device Configuration Utility. Settings should be:
l CS I/O Mode: SDC Address 8
l CS I/O ME Baud Rate: 115.2k
l RS-232 Mode: Modem (default)
l Baud Rate:
l 115.2k fixed for CR1000X series, CR300 series, CR6 series, CR1000, CR3000,
CR800 series, CR5000, and GRANITE 6/9/10 data loggers
l 9600 for CR10X, CR10X-PB, CR510, CR510-PB, CR23X, CR23X-PB, and CR200
(X) series data loggers
l 8 data bits, 1 stop bit, no parity
If connecting to RS-232 port:
Null Modem Cable (9 pin, male-to-male) — connects the module to the CR1000X series,
CR300 series, CR1000, CR3000, CR800 series, and CR200(X) series RS-232 port.
CPI/RS-232 RJ45 to DB9 Cable — connects the module to the CR6 series or CR1000X
series CPI/RS-232 port.