#3 NUMERIC PARAM.
(Numeric parameter settings)
Default Range
01: 0 Not used
02: 10(10 %) (1-99) Not used
03: 15(15 lines) (2-99) Not used
04: 12(12 lines) (1-99) RTN signal transmission condition
05: 4 Not used
06: 1 Not used
07: 350 Not used
08: 0 Not used
09: 6 The number of digits in telephone number
compared against TSI signal to bematched
for receiving function
10: 5500(55 seconds) (0-9999) Line connection detection time (T0 timer)
11: 3500(35 seconds) (0-9999) Not used
12: 0 Not used
13: 0 Not used
14: 0 Not used
15: 120(1200 ms) (0-999) Hooking detection time
16: 4(4 seconds) (0-9) Pseudo RBT transimission from CML on time
until start
17: 100(1000 ms) (0-999) Pseudo RBT signal pattern: On time
18: 0(0 ms) (0-999) Pseudo RBT signal pattern: On time (short)
19: 400(4000 ms) (0-999) Pseudo RBT signal pattern: On time (long)
20: 100(1000 ms) (0-999) Pseudo ring pattern: On time setting
21: 0(0ms) (0-999) Pseudo ring pattern: On time (short)
22: 400(4000 ms) (0-999) Pseudo ring pattern: On time (long)
23: 4 (0-9) FAX/TEL switching function signal detection
level
24: 10 (0-20) Pseudo-RBT signal transmission level
25: 60(60 seconds) (0-999) Answering machine connection function
signal detection time
26: 3 (0-9) Answering machine connection function
no sound detection level
27: 20 Not used
28: 0 Not used
29: 0 Not used
30: 15 Not used
Figure 1-7 Service data(page 3)
*No. 01, 05,06,08,12,14,27-30 are not used. Do not change their settings.