EasyManua.ls Logo

Canon MX884 - Page 20

Canon MX884
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
failed.
##281 TX Re-transmission of the procedure signal has been
attempted the specified number of times, but
failed.
- Try a higher transmission level.
##282 TX Re-transmission of the procedure signal has been
attempted the specified number of times, but
failed.
- Try a higher transmission level.
##283 TX Re-transmission of the procedure signal has been
attempted the specified number of times, but
failed.
- Try a higher transmission level.
##284 TX After TCF transmission, DCN has been received. - Set the receiving machine ready for
reception.
##285 TX After EOP transmission, DCN has been received. - Re-send the fax.
##286 TX After EOM transmission, DCN has been
received.
- Re-send the fax.
##287 TX After MPS transmission, DCN has been received. - Re-send the fax.
##288 TX After EOP transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##289 TX After EOM transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##290 TX After MPS transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##670 TX In V.8 late start, the DIS V.8 ability from the
receiving machine was detected, and CI was sent
in response; however, the procedure failed,
causing T1 time-over.
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##671 RX In V.8 call reception, the procedure fails to
proceed to phase 2 after CM detection, causing
T1 time-over.
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##672 TX In V.34 transmission, the procedure fails to
proceed from phase 2 to phase 3 or later, causing
T1 time-over
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##673 RX In V.34 reception, the procedure fails to proceed
from phase 2 to phase 3 or later, causing T1 time-
over
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##674 TX In V.34 transmission, the procedure fails to
proceed from phase 3 or 4 to the control channel
or later, causing T1 time-over
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##675 RX In V.34 reception, the procedure fails to proceed
from phase 3 or 4 to the control channel or
further, causing T1 time-over
- In bit 0 of the service data #1 SSSW
SW28, prohibit the V.8 / V.34
procedure of the sending machine.
##750 TX After transmitting PPS-NULL in ECM - Try a higher transmission level.
15 / 76

Table of Contents

Related product manuals