CONNECTION TO THE MAINS SUPPLY
WARNING: THIS APPLIANCE MUST BE EARTHED
- Check that the power rating of the mains supply is suitable for the maximum power of the
appliance as indicated on the rating label.
- The fuse rating for this appliance is 32amp.
- The appliance is supplied with a mains lead it should be “Hard wired” as follows:
- The “yellow/green” earth wire, which must be connected to a terminal, and has to be about
10mm longer than the other wire.
- The neutral wire has to be connected to the terminal marked with a letter N.
- The Live wire should only be connected to the terminal marked L.
- Mains connection can also be made by fitting a double pole switch with a minimum gap
between the contacts of 3mm, proportionate to the load and complying with the regulations in
force.
THE YELLOW/GREEN EARTH WIRE SHOULD NOT BE CONTROLLED BY
THE SWITCH.
- When a double pole switch is used for mains supply connection it should be easily accessed,
once the appliance is in position.
IMPORTANT:
- Position the mains supply cable so that it is never subjected to a temperature which is more than
50˚C above ambient temperature.
- The electrical safety of the appliance can only be guaranteed when it has been correctly
connected to an efficient earthed power supply, as instructed in the regulations for
electrical safety.
- Caple cannot be held responsible for any damage to persons or objects due to lack of an earth
connection.