12 Instruction manual ST523 / ST853 Please keep this instruction manual for future reference
DUCTED VERSION
Connect the flange to the air evacuation hole with appropriate ducting.
Connect the appliance to the electrical mains through the supply cord.
RECIRCULATING VERSION
Connect the flange with appropriate ducting to convey the air to the top of the cabinet.
Connect the appliance to the electrical mains through the supply cord.
REAR DUCTED VERSION
To duct the appliance to the rear, remove the 18 screws from the motor support.
Take the metal support and motor out (Fig.11).
Rotate the motor to have the air outlet on the rear side and then fix the screws previously
removed (Fig.12).
CONTROL PANEL
A: Light switch on/off
B: Motor switch - speed 1 / OFF
C: Motor switch - speed 2
D: Motor switch - speed 3
E: Motor switch - speed 4
F: 10-minute timer
R E A R DUCTED VERSION
To duct the appliance to the rear, remove the 18 screws from the motor support.
Take the metal support and motor out (Fig.11).
Rotate the motor to have the air outlet on the rear side and then fix the screws
previously removed (Fig.12).
FIG.11
FIG.12