40
ENG
Heos +0300078EN - rel. 1.6 - 23.11.2017
Mask index Par. Description Default UOM Min Max Possible value descr. R/W
Bac10 /bA Select showcase cleaning input position 0 -- 0 5
0: --
1: DI1, ..., 4: DI4
5: MST
R/W
Showcase cleaning input status 0 -- 0 1
0: CLOSED
1: OPEN
R
Select showcase cleaning input logic 0 -- 0 1
0: N.C.; 1: N.A.
R/W
Showcase cleaning input function 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac11 /bb Select inverter alarm input position 0 -- 0 5
0: --
1: DI1, ..., 4: DI4
5: MST
R/W
Inverter alarm input status 0 -- 0 1
0: CLOSED
1: OPEN
R
Select inverter alarm input logic 0 -- 0 1
0: N.C.; 1: N.A.
R/W
Inverter alarm input function 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac12 /bC Select showcase light input position 0 -- 0 MaxPosDin
0: --
1: DI1, ..., 4: DI4
5: MST
R/W
Showcase light input status 0 -- 0 1
0: CLOSED
1: OPEN
R
Select showcase light input logic 0 -- 0 1
0: N.C.; 1: N.A.
R/W
Showcase light input function 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac14 A9 Select virtual digital input 0 -- 0 4 R/W
Display type of virtual digital input 0 -- 0 13
0: --
1: REMOTE ALARM
2: DELAYED REMOTE ALARM
3: ENABLE DEFROST
4: START NETWORK DEF.
5: DOOR CONTACT
6: REMOTE ON/OFF
7: DAY/NIGHT
9: COLD ROOM MAINT.
10: SHOWCASE CLEANING
11: INVERTER ALARM
12: SHOWCASE LIGHTS
13: CURTAIN CONTACT
R
Bac15 /bE Select position of alarm input on compressor 1 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Status of alarm input on compressor 1 0 -- 0 1
0: CLOSED
1: OPEN
R
Select alarm input logic on compressor 1 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Alarm input function on compressor 1 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac16 /bF Select position of alarm input on compressor 2 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Status of alarm input on compressor 2 0 -- 0 1
0: CLOSED
1: OPEN
R
Select alarm input logic on compressor 2 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Alarm input function on compressor 2 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac17 /bG Select position of alarm input on compressor 3 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Status of alarm input on compressor 3 0 -- 0 1
0: CLOSED
1: OPEN
R
Select alarm input logic on compressor 3 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Alarm input function on compressor 3 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac18 /bH Select position of alarm input on compressor 4 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Status of alarm input on compressor 4 0 -- 0 1
0: CLOSED
1: OPEN
R
Select alarm input logic on compressor 4 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Alarm input function on compressor 4 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac19 /bI Select position of alarm input on compressor 5 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Status of alarm input on compressor 5 0 -- 0 1
0: CLOSED
1: OPEN
R
Select alarm input logic on compressor 5 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Alarm input function on compressor 5 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bac20 /bI Select dual temperature valve output position 0 -- 0 5
0: --
1: ID1, ..., 4: ID4
5: U01, ..., 14: U10
R/W
Dual temperature valve output status 0 -- 0 1
0: CLOSED
1: OPEN
R
Select dual temperature valve output logic 0 -- 0 1
0: N.C.; 1: N.O.
R/W
Dual temperature valve output function 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R
Bad01 /EA Select fan output 1 position 6 -- 0 8
0: --
1: DO1, ..., 8: DO8
9: Y1
10: Y2
11: Y3
R/W
Fan output 1 status 0 -- 0 1
0: OPEN
1: CLOSED
R
Select fan output 1 logic 0 -- 0 1
0: N.A; 1: N.C.
R/W
Fan output 1 function 0 -- 0 1
0: NOT ACTIVE
1: ACTIVE
R