76
humiSteam - cod. +030221914 rel. 5.2 - 07.11.2005
12.TECHNICAL SPECIFICATIONS
Model UE001* UE003* UE003** UE005* UE005** UE008** UE009* UE010** UE015** UE025** UE035** UE045** UE065**
steam
connection (diam. mm) 208-230 V 22/30 30 2x40
400-460-575 V 22/30 30 1x40 2x40
outlet pressure limits (Pa) 0 - 2000 0 - 1600 0 - 1700 0 - 2300
supply water
connection
3
/
4
“G
temperature limits (°C) 1 to 40
pressure limits (MPa) 0.1 to 0.8 (1 to 8 bar)
hardness limits (°fH)
40
instant flow-rate (l/min) 0,6 1.2 4 7
conductivity range (µS/cm) 125 - 1250
drain water
connection (diam. mm) 40
typical temperature (°C)
100
instant flow-rate (l/min) 5 22,5
environmental conditions
ambient operating temperature (°C) 1 to 40
ambient operating humidity (% rH) 10 to 60
storage temperature (°C) -10 to 70
storage humidity (% rH) 5 to 95
index of protection IP20
electronic controller
type UES-UEP-UEH-UEA
auxiliary voltage / frequency (V - Hz) 24 / 50-60
maximum auxiliary power (VA) 30 40
probes inputs for versions C and P input impedance: 15k
Ω
, range 0-10 Vdc
(general characteristics)
probe inputs for versions H and T selectable by signal: 0 to 1 Vdc, 0 to 10 Vdc, 2 to 10 Vdc, 0 to 20 mA, 4 to 20 mA
(general characteristics) input impedance: 60 k
Ω
with signals: 0 to 1 Vdc, 0 to 10 Vdc, 2 to 10 Vdc
50
Ω
with signals: 0- to 20 mA, 4 to 20 mA
power to active probes for versions H or T 28 V (24Vac rectified), Imax= 250 mA
(general characteristics) 12 Vdc 5%, Imax= 50 mA
alarm relay outputs for versions H or T 250 V 5A (2A) - microinterruption action type 1C
(general characteristics)
alarm relay and dehum. outputs for vers. H or T 250 V 8A (2A) - microinterruption action type 1C
(general characteristics)
remote enabling input (general characteristics) free contact; max. resistance 50
Ω
; Vmax= 24 Vdc; Imax= 5 mA
serial communication for versions H or T RS-485 two-wire
power
rated power supply voltage: 208V - 1~N code U
instant steam production
(1)
(kg/h) 1.5 3.0 5.0 8,7
power input at rated voltage (kW) 1.12 2.25 3.75 6,52
rated power supply voltage: 230V - 1~N code D
instant steam production
(1)
(kg/h) 1.5 3.0 5.0 9
power input at rated voltage (kW) 1.12 2.25 3.75 6,75
rated power supply voltage: 208V - 3~ code W
instant steam production
(1)
(kg/h) 3.0 5.0 8.0 10.0 15.0 25 35 45
power input at rated voltage (kW) 2.25 3.75 6.00 7.50 11.25 18.75 26.25 33.75
rated power supply voltage: 230V - 3~ code K
instant steam production
(1)
(kg/h) 3.0 5.0 8.0 10.0 15.0 25 35 45
power input at rated voltage (kW) 2.25 3.75 6.00 7.50 11.25 18.75 26.25 33.75
rated power supply voltage: 400V - 3~ code L
instant steam production
(1)
(kg/h) 3.0 5.0 8.0 10.0 15.0 25 35 45 65
power input at rated voltage (kW) 2.25 3.75 6.00 7.50 11.25 18.75 26.25 33.75 48.75
rated power supply voltage: 460V - 3~ code M
instant steam production
(1)
(kg/h) 3.0 5.0 8.0 10.0 15.0 25 35 45 65
power input at rated voltage (kW) 2.25 3.75 6.00 7.50 11.25 18.75 26.25 33.75 48.75
rated power supply voltage: 208V - 1~N code U
instant steam production
(1)
(kg/h) 3.0 5.0 8.0 10.0 15.0 25 35 45 65
power input at rated voltage (kW) 2.25 3.75 6.00 7.50 11.25 18.75 26.25 33.75 48.75
Tab. 12.1
* single-phase, ** three-phase.
(1)
the average steam production is affected by factors such as: the ambient temperature, the quality of the water and the steam distribution system