Appendix D
EMC Precautions
Special precautions regarding EMC (Electromagnetic
Compatibility) and the Care Wise C-Trak
®
Apollo System.
The C-Trak
®
Apollo System conforms to IEC 60601-1-2 standards
for electromagnetic compatibility. However, the Apollo System
requires special precautions regarding EMC and needs to be
installed and put in service according to the EMC information
provided in this User Guide. The customer/user of the C-Trak
®
CW4000 should assure that it is used in such an environment.
The following may result in increased emissions
or decreased immunity of the Care Wise
CW4000 Apollo System:
The use of accessories, cables or other components
other than those specified, provided or sold by
Care Wise (see Product/Parts List in Appendix F).
Unauthorized replacement parts or additional
components internal to the Apollo System.
The C-Trak
®
CW4000 is intended for use in an
electromagnetic environment in which radiated
RF (Radio Frequency) disturbances are controlled.
Interference may occur in the vicinity of equipment
marked with the symbol .
The use of portable or mobile RF communications
equipment within close proximity to the Apollo System
or other nearby Medical Electrical Equipment.
Recommended separation distance:
d=1.2√P (150 kHz to 80 MHz)
d=1.2√P (80 MHz to 800 MHz)
d=2.3√P (800 MHz to 2.5 GHz)
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in meters (m).
The use either adjacent to, or stacked with other
equipment, unless previously verified that such
use does not aect performance.
Electromagnetic environment guidance:
The C-Trak
®
CW4000 uses RF (Radio Frequency) energy
only for its internal function. Therefore, its RF emissions
are very low and are not likely to cause any interference
in nearby electronic equipment.
The C-Trak
®
CW4000 is suitable for use in all establishments
other than domestic and those directly connected to the
public low-voltage power supply network that supplies
buildings used for domestic purposes.
Use on floors that are wood, concrete or ceramic tile.
If floors are covered with synthetic material, the relative
humidity should be at least 30%.
Main power should be that of a typical
commercial or hospital environment.
Power frequency magnetic fields should be at
levels of a typical location in a typical commercial
or hospital environment.