30
8.5 INSPECTIONS
Once installation and adjustments have been performed, proceed to the following inspections:
a) Check correct smoke evacuation;
b) Check water-tightness;
c) Check functioning of system;
d) Check the thermo fireplace efficiency
8.6 PROPER FUNCTIONING
Thermo fireplace CARINCI EVOLUTION, during performance tests, was loaded with wood and adjusted in this way:
CARINCI EVOLUTION 150/200 CARINCI EVOLUTION 250/300
Loads for efficiency test
4.4 kg (n. 4 beechwood logs 30 cm ) 6.0 kg (n. 5 beechwood logs 30 cm)
Combustive air range adjustment
Primary air: 2 mm opening width
Secondary air: wide open
Glass screen air: 1/3 open
Primary air: 2 mm opening width
Secondary air: wide open
Glass screen air: 1/3 open
Test Duration
45 min 45 min
9.0 COVERING
The thermo fireplace CARINCI must be fully upholstered, except only for the glass shutter.
Any maintenance of the sliding can be performed without dismantling any element of the covering but only removing the
side covering (see figure) (see figure)
The Carinci Group SpA recommends, before upholstering the thermo fireplace, to make all efficiency checks of the thermo
fireplace and keep it running for a few weeks.
In the testing phase, it is possible to make some intervention or replacement but, once the covering is assembled, the
customer attests to the validity of the product in all its performances, thus the thermo fireplace replacement right loses its
validity.
The Carinci Group SpA, with its qualified technicians is always available for guidance and/or advices, please contact our cus-
tomer service at +39 0776/812704 Monday-Friday working hours.