Flush Volume & Stall Setup
Three Stall Installations
4
5
3
1
2
Blank Access Panel
*
Ø20 sparge pipe
*
Reducer to Ø40
copper pipe (supplied)
Refer to specifications of the selected urinal.
400mm - 420mm
Frame
45mm
600mm 600mm
950mm
Recommended
335mm to
access panel
centre line
Centre Line Button
(standard mounting)
Finished Floor Level
Single Remote Button
Datum
Adjustment
Screw
Bucket
8
5.8L = Three Stall Urinal
For three stall installations the outlet valve must first be configured by following the
conversion instructions adjacent.
The water level in the cistern must then be set to the1.8Lwater level mark, using the
float adjustment screw located on the side of the inlet valve.
The pneumatic tube must be connected to the full flush position.
= Full Flush Position
Conguring Flush Volume
Remove Outlet Valve, refer to page 17.
Using a screw driver lever the bucket
hangers over the hooks, allowing it to
sit as low as possible.
5
Replace parts back into Cistern.
Set Water Level using the adjustment
screw.
.
The Water Level should be set to the
“1.8L” mark on the inside of the cistern.
NOTE:
When installing the
Remote Mounting Box in
this position, please refer
to the ‘Installation Note’ on
page 5