INDOOR UNIT INSTALLATION
Step 1: Select Installation Location
NOTE: Before installing the indoor unit, refer to the label on the unit box to ensure that the model number of the indoor unit matches the
model number of the outdoor unit.
The following are standards that will help you select an appropriate location for the unit. Proper installation locations meet the following standards:
NOTE: If there is no fixed refrigerant piping: While choosing a location, be aware that you should leave ample room for a wall hole (see Drill
wall hole for connecting piping step) for the signal cable and refrigerant piping that connect the indoor and outdoor units. The default
position for all piping is the right side of the indoor unit (while facing the unit). However, the unit can accommodate piping to both the
left and right.
Good air circulation
Convenient drainage
Noise from the unit will
not disturb other people.
Firm and solid—the
location will not vibrate
Strong enough to support
the weight of the unit
A location at least
3.2 ft/1m from all
other electrical
devices (e.g., TV, radio,
computer)
Distance from ceiling is determinded
by the installation method.
If you do not need the kick stand to prop up the unit:
Finish the pipe and cable connections before mounting the
indoor unit on the wall. If the installation height is limited, 1.96in.
(5cm) from the ceiling is allowable, however this can lower product
performance. To ensure enough space to install and remove
the top air filter, keep at least 3.93in (10cm) or more from the ceiling.
If you need the kick stand to prop up the unit:
If connecting pipe and cable with front panel open, the
minimum distance from ceiling is 8.67in (22cm) or more. If the
connecting pipe and cable is without the front panel (remove it),
the minimum distance from ceiling is 4.33in (11cm) or more.
DO NOT install unit in the following locations:
Near any source of heat, steam, or
combustible gas
1HDUÀDPPDEOHLWHPVVXFKDVFXUWDLQVRU
clothing
Near any obstacle that might block air
circulation
Near the doorway
In a location subject to direct sunlight