45MAHAQ: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
3
NOTE: The air conditioner’s circuit board (PCB) is designed with a
fuse to provide overcurrent protection. The specifications of
the fuse are printed on the circuit board, for example:
T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/
250VAC, T20A/250VAC, T30A/250VAC,etc.
NOTE: Only a blast-proof ceramic fuse can be used.
FOR FLAMMABLE REFRIGERANTS
Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an operating
gas appliance or an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odor.
WA RNING
PERSONAL INJURY AND PROPERTY DAMAGE HAZARD
For continued performance, reliability, and safety, the only
approved accessories and replacement parts are those specified by
the equipment manufacturer. The use of non-manufacturer
approved parts and accessories could invalidate the equipment
limited warranty and result in a fire risk, equipment malfunction,
and failure.
Review the manufacturer’s instructions and replacement parts
catalogs available from your equipment supplier.
WARNING
Only use the specified wire. If the wire is damaged, it must be
replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard. The product must be
properly grounded at the time of installation, or electric shock may
occur.
For all electrical work, follow all local and national wiring
standards, regulations, and the Installation Manual. Connect the
cables tightly, and clamp them securely to prevent external forces
from damaging the terminal. Improper electrical connections can
overheat and cause fire, and may also cause shock. All electrical
connections must be made according to the Electrical Connection
Diagram located on the panels of the indoor and outdoor units.
All wiring must be properly arranged to ensure that the control
board cover can close properly. If the control board cover is not
closed properly, it can lead to corrosion and cause the connection
points on the terminal to heat up, catch fire, or cause electrical
shock.
Disconnection must be incorporated in the fixed wiring in
accordance with NEC, CSA and Local Codes. Do not share the
electrical outlet with other appliances. Improper or insufficient
power supply can cause fire or electric shock.
If connecting power to fixed wiring, an all-pole disconnection
device which has at least 3mm clearances in all poles, and have a
leakage current that may exceed 10mA, the residual current device
(RCD) having a rated residual operating current not exceeding
30mA, and disconnection must be incorporated in the fixed wiring
in accordance with NEC, CSA and Local Codes.
WA RNING
Turn off the air conditioner and disconnect the power before
performing any installation or repairing. Failure to do so can cause
electric shock.
Installation must be performed by an authorized dealer or specialist.
Defective installation can cause water leakage, electrical shock, or
fire. Installation must be performed according to the installation
instructions.
Improper installation can cause water leakage, electrical shock, or
fire. Contact an authorized service technician for repair or
maintenance of this unit. This appliance shall be installed in
accordance with national wiring regulations.
Only use the included accessories, parts, and specified parts for
installation. Using non-standard parts can cause water leakage,
electrical shock, fire, and can cause the unit to fail.
Install the unit in a firm location that can support the unit’s weight.
If the chosen location cannot support the unit’s weight, or the
installation is not done properly, the unit may drop and cause
serious injury and damage. Install drainage piping according to the
instructions in this manual. Improper drainage may cause water
damage to your home and property. For units that have an auxiliary
electric heater, do not install the unit within 3 feet (1 meter) of any
combustible materials.
If combustible gas accumulates around the unit, it may cause fire.
Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced
service technicians for disconnection and re-installation of the unit.
Read the information for details in “indoor unit installation” and
“outdoor unit installation” sections.
WA RNING