38
ELECTRICAL DATA
38HDR
UNIT SIZE
V --- P H --- H z
VOLTAGE RANGE* COMPRESSOR OUTDOOR FAN MOTOR
MIN CKT
AMPS
FUSE/HACR
BKR AMPS
Min Max RLA LRA FLA NEC Hp kW Out
018 208/230---1 ---60 187 253 9.0 48.0 0.8 0.125 0.09 12.1 20
024 208/230---1 ---60 187 253 12.8 58.3 0.8 0.125 0.09 16.8 25
030 208/230---1 ---60 187 253 14.1 73.0 1.5 0.25 0.19 19.1 30
036
208/230---1 ---60 187 253 14.1 77.0 1.5 0.25 0.19 19.1 30
208/230---3 ---60 187 253 9.2 71.0 1.5 0.25 0.19 13.0 20
4 6 0 --- 3 --- 60 414 506 5.6 38.0 0.8 0.25 0.19 7.9 15
048
208/230---1 ---60 187 253 21.8 117.0 1.5 0.25 0.19 28.7 50
208/230---3 ---60 187 253 13.8 83.1 1.5 0.25 0.19 18.7 30
4 6 0 --- 3 --- 60 414 506 6.2 41.0 0.8 0.25 0.19 8.6 15
060
208/230---1 ---60 187 253 26.4 134.0 1.5 0.25 0.19 34.5 60
208/230---3 ---60 187 253 17.7 110.0 1.5 0.25 0.19 23.6 40
4 6 0 --- 3 --- 60 414 506 7.8 52.0 0.8 0.25 0.19 10.6 15
38QRR
UNIT SIZE
V --- P H --- H z
VOLTAGE
RANGE*
COMPRESSOR OUTDOOR FAN MOTOR
MIN CKT
AMPS
FUSE/HACR BKR
AMPS
RLA LRA FLA NEC Hp kw Out
Min Max
018 208/230---1 ---60 187 253 9.8 48.0 0.8 0.125 0.09 12.1 20
024 208/230---1 ---60 187 253 12.8 58.3 0.8 0.125 0.09 18.8 30
030 208/230---1 ---60 187 253 12.8 64.0 1.5 0.25 0.19 17.5 30
036
208/230---1 ---60 187 253 15.5 77.0 1.5 0.25 0.19 20.9 30
208/230---3 ---60 187 253 10.1 71.0 1.5 0.25 0.19 14.1 20
4 6 0 --- 3 --- 60 414 506 5.6 38.0 0.8 0.25 0.19 7.9 15
048
208/230---1 ---60 187 253 26.5 117.0 1.5 0.25 0.19 34.6 50
208/230---3 ---60 187 253 16.7 83.1 1.5 0.25 0.19 22.4 30
4 6 0 --- 3 --- 60 414 506 7.3 41.0 0.8 0.25 0.19 10.0 15
060
208/230---1 ---60 187 253 26.4 134.0 1.5 0.25 0.19 34.5 60
208/230---3 ---60 187 253 17.7 110.0 1.5 0.25 0.19 23.6 40
4 6 0 --- 3 --- 60 414 506 7.8 52.0 0.8 0.25 0.19 10.6 15
UNIT
VOLTAGE
V --- P h --- 6 0 H z
VOLTAGE
RANGE*
FAN
FLA
HEATER POWER
MINIMUM
WIRE SIZE
(AWG)
MIN. MAX. kW FLA MCA MOCP FLA
40QAC024--- 3 208/230 ---1 187 253 0.50 0.63 15.0 0.50 14
40QAC036--- 3 208/230 ---1 187 253 1.30 1.60 15.0 1.30 14
40QAC048--- 3 208/230 ---1 187 253 1.60{ 2.00 15.0 1.60 14
40QAC060--- 3 208/230 ---1 187 253 2.60} 3.30 15.0 2.60 14
40QAQ024--- 3 208/230---1 187 253 0.50 2.00 8.66 9.29 15.0 11.29 14
40QAQ036--- 3 208/230---1 187 253 1.30 3.00 13.00 17.70 20.0 14.30 14
40QAQ048--- 3 208/230---1 187 253 1.60{ 4.00 17.40 23.80 25.0 19.00 12
40QAQ060--- 3 208/230---1 187 253 2.60{ 5.00 21.70 28.70 30.0 24.30 10
LEGEND
FLA --- Fu l l L o a d A m p s
LRA --- L o ck e d Ro t o r A m p s
MCA --- Minimum Circuit Amps
RLA --- RatedLoadAmps
NOTES
* P ermissible limits of the voltage range at which the unit will operate
satisfactorily
{ Onefanis1.1amps,thesecondfanis0.5amps.
} Two fan s each operating at 1.3 amps.
40QAC/38HDR -- 40QAQ/38QR
R

Other manuals for Carrier 38HDR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38HDR and is the answer not in the manual?

Carrier 38HDR Specifications

General IconGeneral
BrandCarrier
Model38HDR
CategoryAir Conditioner
LanguageEnglish

Related product manuals