EasyManua.ls Logo

Carrier 38MARB - IPM Malfunction or IGBT Over-Strong Current Protection

Carrier 38MARB
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38MARB: Service Manual
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
39
DIAGNOSIS AND SOLUTION (CONT)
IPM Malfunction or IGBT over-strong current protection (PC00)
Description: If the IPM sends an abnormal voltage signal to the compressor drive chip, the LED displays the failure code and the unit turns off.
Recommended parts to repair:
Communication wires
IPM module board
Outdoor fan assembly
Compressor
Outdoor PCB
Troubleshooting
YES
NO
Is the IPM
terminal resistance
uniform?
NO
YES
Please refer to the “Fan Speed is
operating outside of normal range”
malfunction.
NO
YES
YES
NO
YES
NO
Check the wiring between
the PCB and the compressor.
Does an error exist?
Ensure proper connections or
replace the wires and connectors.
Correct the installation, tighten the
screws and apply silicon grease.
Check if the IPM
is installed correctly.
IPM continuity check
Replace the IPM board or
replace the outoor PCB.
Check the outdoor fan and the
outdoor unit’s ventilation.
Is it in working order?
Check the compressor
resistance values.
Are they the same? Replace the compressor.
Replace the outdoor PCB.

Table of Contents

Other manuals for Carrier 38MARB

Related product manuals