Hi Wall Split Air Conditioners
53QPCT 18C-24C Cool Only
53QPCT 18H-24H
Heat Pump
Rev. (0) - 2013
220-240V ~ 50Hz 1Ph
R
2
2
Quality
Management System
ISO 9001 : 2008
Certicate No.: QS-5519HH
Enviromental
Management System
ISO 14001 : 2004
Certicate No : 12 104 30334 TMS
Safety
Management System
BS OHSAS 18001 : 2007
Certicate No : 12 116 30334 TMS
03502767
Carrier is committed to continuously improving its products according to national and international standards
to ensure the highest quality and reliability standards, and to meet market regulations and requirements.
All specications subject to change without prior notice according to Carrier policy of continuous development.
INSTALLATION MANUAL
Question and Answer IconNeed help?

Do you have a question about the Carrier 42QPCT18H-708F and is the answer not in the manual?

Carrier 42QPCT18H-708F Specifications

General IconGeneral
RefrigerantR410A
Phase1
Indoor Unit TypeWall Mounted
Indoor Unit Weight22 lbs
Outdoor Unit Weight77 lbs
Cooling Capacity18000 BTU/h
Heating Capacity18000 BTU/h

Summary

General Notes for Installers

Precautions Before Installation

Indoor Unit Installation Location

Outdoor Unit Installation Location

Minimum Clearances for Single Outdoor Unit Installation

Specifies required clearances around the outdoor unit for single installations.

Minimum Clearances for Serial Outdoor Unit Installation

Specifies required clearances for serial outdoor unit installations.

Installation Location Check List

Installation Chart

Indoor Unit Installation

Preparation Steps for Indoor Unit

Steps to prepare the indoor unit before mounting it.

Indoor Unit Installation Steps

Step-by-step instructions for mounting the indoor unit.

Outdoor Unit Installation

Preparation Steps for Outdoor Unit

Steps to prepare the outdoor unit before mounting.

Wall Installation Steps

Instructions for assembling and mounting the wall support for the outdoor unit.

Connecting Refrigerant Piping Lines

Instructions for Connecting Refrigerant Piping Lines

Detailed instructions on connecting refrigerant piping lines correctly.

Refrigerant Piping Line Usage Guidelines

Guidance on using refrigerant piping lines based on unit configuration.

Refrigerant Charge Calculation

Instructions for calculating and adding refrigerant charge.

Refrigerant Piping Preparation Steps

Step-by-step guide for preparing piping lines before making connections.

Air Purging of Refrigerant Piping Lines

Introduction to air purging procedures for the system.

Air Purging Introduction

Explains the necessity and effects of air in the refrigeration circuit.

Air Purging Using Outdoor Unit Refrigerant

Details the air purging method using refrigerant from the outdoor unit.

Air Purging Using Vacuum Pump

Details the air purging method using a vacuum pump.

Refrigerant Leak Check

Methods for checking refrigerant leakage after connections.

Connecting Condensate Drain Line

Connecting Electrical Wiring

Wiring: Power Supply to Circuit Breaker

Details wiring between the power supply and the unit's circuit breaker.

Wiring: Indoor;Outdoor Units to Circuit Breaker

Details wiring between indoor, outdoor units and the circuit breaker.

Finishing Installation Steps

Test Running Procedures

After Installation Check List

Self-Diagnostic Function for Malfunctions

Related product manuals