CAUTION
Wrong wiring connection may cause some electrical parts burn out.
Be sure to comply with local rule on running the wire from indoor unit
to outdoor unit (size of wire and wiring method, etc.).
Every wire must be connected firmly.
If incorrect or incomplete wiring is carried out, it will cause an ignition
or smoke.
Prepare the power supply for exclusive use with the air conditioner.
This product can be connected to the mains.
Connection to fixed wiring : A switch which disconnects all poles and
has a contact separation of at least 3 mm must be incorporated in the
fixed wiring.
OTHERS
Gas Leak Test
Model 18 Class 22 Class
Power source
220-240V Single phase, 50Hz
220-230V Single phase, 60Hz
Maximum running current
10.0A
13.5A
Plug socket & fuse rating
13A
16A
Power cord H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
CAUTION
NOTE : Connecting cable
Wire type : More than 1.5 mm
2
(H07RN-F or 60245 IEC66) or 1.3 mm
2
(AWG-16)
Test Operation
Auto Restart Setting
How to set the Auto Restart
1. Press and hold the [RESET] button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp [
] blink 5 time/sec
for 5 seconds)
2. Press and hold the [RESET] button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp [
] does not
blink)
In case of ON timer or OFF timer are set, AUTO RESTART
OPERATION does not activate.
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
To switch the TEST RUN (COOL) mode, press [RESET] button for 10
seconds. (The beeper will make a short beep.)
RESET button
Information
The product was shipped with Auto Restart function in the off position.
Turn it on as required.
Check the flare nut
connections for the gas
leak with a gas leak
detector or soap water.
Check places for
the indoor unit.
Check places for
the outdoor unit.
Remote Control A-B Selection
When two indoor units are installed in the same room or adjacent two
rooms, if operating a unit, two units may receive the remote control signal
simultaneously and operate. In this case, the operation can be preserved
by setting either one remote control to B setting. (Both are set to A setting
in factory shipment.)
The remote control signal is not received when the settings of indoor unit
and remote control are different.
There is no relation between A setting/B setting and A room/B room when
connecting the piping and cables.
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed near.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display (Picture 1).
4. Press [MODE] during pushing [CHECK]. “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized (Picture 2).
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not “A” display.
3. Default setting of Remote Control from factory is A.
1 2
RESET
0
1
0
1
01
01
30
30
40
40
L
N
1
2
3
Stripping length of the connecting cable
Connecting cable
Power cord
Terminal block
Earth line
Connecting cable
Power cord
Earth line
NOTE
Wire type : H07RN-F or 60245 IEC66 (1.5 mm
2
or more)
Electrical Work
1. The supply voltage must be the same as the rated voltage of the air
conditioner.
2. Prepare the power source for exclusive use with the air conditioner.