Carrier 1110651814 (EN)
5
ES
FR
IT
VT
PL
RU
CR
TR
NL
GR
SV
FI
DK
BG
EE
SK
SI
EN
CAUTION
•
Be sure to refer to the wiring system diagram labeled inside the front
panel.
•
Check local electrical cords and also any specific wiring instructions or
limitations.
Wiring Connection
How to connect the connecting cable
Wiring of the connecting cable can be carried out without removing
the front panel.
1. Remove the air inlet grille.
Open the air inlet grille upward and pull it toward you.
2. Remove the terminal cover and cord clamp.
3. Insert the connecting cable (according to the local rule) into the pipe hole
on the wall.
4. Take out the connecting cable through the cable slot on the rear panel so
that it protrudes about 15 cm from the front.
5. Insert the connecting cable fully into the terminal block and secure it
tightly with screws.
6. Tighten firmly but not over 1.2 N·m (0.12 kgf·m)
7. Secure the connecting cable with the cord clamp.
8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoor
unit.
NOTE
•
Use stranded wire only.
•
Wire type : More than 1.5 mm
2
(H07RN-F or 60245 IEC66) or 1.3 mm
2
(AWG-16)
1
2
3
110 mm
20 mm
10 mm
80 mm
Earth line
about 15 cm
Screw
Terminal cover Terminal block
Cord clamp
Screw
Earth line
Connecting cable
Connecting cable
Stripping length of the connecting cable
How to Connect Remote Controller
for Wire Operation
Indoor unit
Control wire
Remote controller
For remote controller
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on figure 7.
4. Insert control wire from rear side of remote controller as shown on
figure 8.
5. Fix control wire which arrange as shown on figure 9 and ! to terminal
by provided screws (tighten firmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on figure ".
7. Fix provided screw (∅3.1 x 16L) on the wall to hang remote controller as
shown on figure #.
8. Mark and arrange hole for fix below screw (∅3.1 x 25L) as shown on
figure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (∅3.1 x 25L) to fix battery cover together with wall as
shown on figure $ (tighten firmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
7 8
Polyester sheet close hole
for insert control wire
Control wire
30 mm
10 mm
* Wire size 28-22 AWG (0.08~0.32 mm
2
)
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
9 !
For indoor unit
1. Open the air inlet grille upward.
2. Securely remove four screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
figure 1.
4. After removing the front panel, remove the screws and Display unit from
the unit as shown on figure 2 then open the front cover of Display unit as
shown on figure 3.
5. Arrange the control wire as detail and specification as shown on figure 4.
6. Securely connect the control wire to terminal of Display unit board as
shown on figure 5 (tighten firmly but not over 0.12 N·m (0.01 kgf·m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of figure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on figure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
Control wire
Terminal
Tighten firmly but not over
0.25 N·m (0.03 kgf·m)
* Wire size 28-22 AWG (0.08~0.32 mm
2
)
Outer diameter not over 4.7 mm,
control wire length 30 m. or less.
Display unit
Display board
2
3