Carrier 42UQV050M Series - Indoor Unit; Installation Place; Cutting a Hole and Mounting Installation Plate; Remote Control

Carrier 42UQV050M Series
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Carrier 1110651814 (EN)
4
To
unit o
ut line
240
mm
To
uni
t out line
35m
m
To unit
ou
t line
240
m
m
Offset 23mm from the right side edge is
the center of pipe hole
To
u
ni
t out
line
120m
m
0 23 35 120 180 240
Offset 85mm from the left side edge is
the center of pipe hole
170
170
50
40
85
132
23
65 mm
m from the right side edge is
e
center of pipe hole
35 120 180 240
23 mm
65
mm
INDOOR UNIT
Installation Place
Remote control
A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment. (This is necessary to prevent image disturbances or
noise interference.)
The location of the remote control should be determined as shown below.
Cutting a Hole and Mounting
Installation Plate
When the installation plate is directly mounted
on the wall
1. Securely fit the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below figure.
3. Install the installation plate horizontally in the wall.
NOTE
When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
A place which provides the spaces around the indoor unit as shown in the
diagram
A place where there are no obstacles near the air inlet and outlet
A place which allows easy installation of the piping to the outdoor unit
A place which allows the front panel to be opened
The indoor unit shall be installed as top of the indoor unit comes to at
least 2 m height. Also, it must be avoided to put anything on the top of the
indoor unit.
The center of the pipe hole is
above the arrow.
Pipe hole
In case of block, brick, concrete or similar type walls, make 5 mm dia.
holes in the wall.
Insert clip anchors for appropriate mounting screws 7.
Hook
Hook
Hook
Pipe hole
Pipe hole (65 mm)
Weight
Indoor unit
Thread
2 m or more from floor
Installation plate
(Keep horizontal direction.)
5 mm dia. hole
Clip anchor
(local parts)
Anchor bolt
Projection
15 mm or less
Cutting a hole
When installing the refrigerant pipes from the rear
Mounting the installation plate
NOTE
Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
CAUTION
Direct sunlight to the indoor unit’s wireless receiver should be avoided.
The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner’s manual.)
1. After determining the pipe hole position on the mounting plate (A), drill
the pipe hole (65 mm) at a slight downward slant to the outdoor side.
7 Mounting screw
4 x 25 s
CAUTION
Failure to firmly install the unit may result in personal injury and property
damage if the unit falls.
CAUTION
When installing the installation plate with a mounting screw, do not use
the anchor bolt holes. Otherwise, the unit may fall down and result in
personal injury and property damage.
Anchor bolt holes
1 Installation plate
7 Mounting
screw
54
45
5
7
Indoor unit
(Side view) (Top view)
Indoor unit
Remote control
Remote
control
Reception
range
Reception range