DIMENSIONS
2-7/16"
1-1/8"
28-7/8"
(733mm)
25-1/4"
22-9/16"
JUNCTION BOX
LOCATION
7/8" DI A
ACCESSORY
1/2" (13 mm) DIA.
THERMOSTAT WIRE ENTRY
3-15/16" (84mm)
LEFT HAND GAS
ENTRY
33-5/16"
24-7/8"
5-1/2"
7/8" (22mm) DIA.
ACCESSORY
11/16"
21-5/8"
BOTTOM INLE T
1-11/16"
13/16"
11/16"
4-13/16"
AIRFLOW
19"
OUTLE T
13/16"
11/16"
8-9/16"
VENT OUTLE T
5 PLACES (TYP)
3-3/4"
1-3/4" DIA.RIGHT HAND
GAS ENTRY
7/8" DIA. K.O. WIRE ENTRY
SIDE INLE T
14-7/8"
7/8" DIA. ACCESSORY
1-1/4"
1"
22-1/16"
A
D
F
E
(FLUE COLLAR)
5-15/16"
(135mm)
24"
CASING
1-5/16"
1/2" DIA. K.O.THERMOSTAT
WIRE ENTRY
ALTERNAT E
JUNCTION BOX
LOCATIONS (TYP)
26-1/8"
1-1/2"
7-3/4"
9-5/8"
11-1/2"
5-1/2"
(664mm)
(641mm)
(573mm)
(22mm)
(846mm)
(17mm)
(549mm)
(
610mm
)
(43mm)
(140mm)
(632mm)
(17mm)
(140mm)
(95mm)
(21mm)
(122mm)
(217mm)
(62mm)
(33mm)
(29mm)
(483mm)
(13mm)
(44mm)
(22mm)
(22mm)
(38mm)
(560mm)
(25mm)
(32mm)
(378mm)
(17mm)
(197mm)
(244mm)
(292mm)
(21mm)
A04037
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM---16 ---in. (406 mm) r ound or 14 1/2 x 12---in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20---in. (508 mm) r o und or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. Th e use of both sideinlets,a
combina tion of 1 side and the bottom, or th e bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
FURNACE SIZE
A
CABINET
WIDTH
IN. (mm)
D
SUPPLY---
AIR WIDTH
IN. (mm)
E
RETURN ---
AIR WIDTH
IN. (mm)
F
CENTER LINE TOP AND
BOTTOM FLUE
COLLAR
IN. (mm)
FLUE
COLLAR*
IN. (mm)
SHIPPING
WT.
LB (KG)
FILTER
MEDIA
CABINET
SIZE
IN. (mm)
070---12
14---3/16
(360)
12---9/16
(319)
12---11/16
(322)
9---5/16 (237) 4 (102) 127 (58) 16 (406)
090---16
17---1/2
(445)
15---7/8
(403)
16---1/8
(410)
11---9/16 (294) 4 (102) 151 (68) 16 (406)
110---20 21 ( 533)
19---3/8
(492)
19---1/2
(495)
13---5/16 (338) 4 (102) 163 (74) 20 (508)
135---22
24---1/2
(622)
22---7/8
(581)
23 (584) 15 ---1/16 (383) 4 (102) 177 (80) 24 (610)
155---22
24---1/2
(622)
22---7/8
(581)
23 (584) 15 ---1/16 (383) 4 (102) 183 (83) 24 (610)
*5 in. or 6 in. (127 or 152 mm) vent connector may be required in some cases.
{5 in. (127 mm) or larger vent is required. Use a 4---5 (102 ---127 mm) or 4 ---6 in. (102---152 mm) vent a dapter between furnace a nd vent connector.
A
Media/
Filter Cabinet
AB C
16" (406 mm) 17" (432) 16
1
/
4"(413) 15" (381)
20" (508 mm) 21" (533) 20
1
/
4"(514) 19" (483)
24" (610 mm) 25" (635) 24
1
/
4"(616) 23" (584)
23
5
/
8
"
23
3
/
8
"
Furnace Side
23
3
/
4
"
Centerline Screw Slots
25
5
/
8
"
Duct Side
24
1
/
2
"
With Flanges Bent Out
23
1
/
8
"
Opening
5
3
/
4
"
C Opening
with Flanges Bent In
B
(600 mm)
(594 mm)
(603 mm)
(146 mm)
(651 mm)
(622 mm)
(587 mm)
58CVA/CVX