59TP6C: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
21
A11437
Fig. 27 – Optional Media Cabinet Accessory
Table 9 – Air Filter Selection and Duct Sizing - In. (mm)
FURNACE
CASING WIDTH
FILTER SIZE
FILTER TYPE
*
*. Recommended to maintain air filter face velocity. See Product Data Sheet
for part number.
SIDE
RETURN
BOTTOM
RETURN
14-3/16 (360)
16 x 25 x 3/4
(406 x 635 x 19)
14 x 25 x 3/4
(356 x 635 x 19)
Washable
17-1/2 (445)
16 x 25 x 3/4
(406 x 635 x 19)
16 x 25 x 3/4
(406 x 635 x 19)
Washable
21 (533)
16 x 25 x 3/4
(406 x 635 x 19)
20 x 25 x 3/4
(508 x 635 x 19)
Washable
24-1/2 (622)
16 x 25 x 3/4
(406 x 635 x 19)
24 x 25 x 3/4
(610 x 635 x 19)
Washable
Table 10 – Air Filter Located in Filter Cabinet
FILTER
CABINET
HEIGHT - IN
(MM)
FILTER SIZE - IN (MM)
*
*. Filters with a side return-air may have a different filter size. Measure the
filter to obtain the correct size.
FILTER
TYPE
†. Recommended to maintain air filter face velocity. See Product Data for part
number.
16 (406)
(1) 16 x 25 x 3/4 (406 x 635 x 19) or
(1) 16 x 25 x 4-5/16 (406 x 635 x 110)
Washable or
Media
20 (508)
(1) 20 x 25 x 3/4* (508 x 635 x 19) or
(1) 20 x 25 x 4-5/16 (508 x 635 x 110)
Washable or
Media*
24 (610)
(1) 24 x 25 x 3/4* (610 x 635 x 19) or
(1) 24 x 25 x 4-5/16 (610 x 635 x 110)
Washable or
Media*
14-3/16 and 17-1/2-in.
Furnace
16-in. Media Cabinet
21-in. Furnace
4-Ton or less, AC
capacity airflow
20-in. Media Cabinet
4-in.
Block Off
Plate
1/2-in.
Screws
20- or 24-in. Media
Cabinet
Bottom Return Plenum
21- or 24-1/2-in.
Furnace
Up to 5-Ton AC
capacity airflow
45°
Transition
20- or 24-in. Media Cabinet
Screw
14-3/16-in. Furnace
Filler plates
Screw
14--3/16- in. Furnace with Filler Plates, Centered
14-3/16-in. Furnace
Filler plate
Screws
14--3/16- in. Furnace with Filler Plates, Off--Set to Right
Media Cabinet Installation Option for
4-Ton or Less A/C Capacity
20- or -24-in. Media Cabinet Installation
with Angled Transition
20- or -24-in. Media Cabinet Installation
for Combination Side and Bottom Return
Media Cabinet Installation
Side Return
21-in. Furnace
up to 5-Ton AC
Capacity
24-1/2-in. Furnace
up to 4-Ton AC
Capacity