5.5. Searching for SAM Module (If Applicable)
“Searching for SAM Module” will appear on the screen to determine if a System
Access Module, used for home automation only, is connected to the system.
The SYSTXCCSAM01 is not compatible with this control. The compatible modules
are SYSTXCCRCT01 and SYSTXCCRWF01. The SAM is used for home
automation purposes and is NOT used to connect the system contro l to the Internet.
NOTE: For more information regarding the SAM Module, reference the latest
version of the application specification entitled “SAM Remote Access Application
Specification, ASCII Proto col Information”, available on HVACpartners.com, or
the System Access Module Installation Instructions.
A13117
5.6. Searching for Zones (If Applicable)
“Zoning -- Searching” will appear on the screen to determine if any zones are
present. The screen will show Zone 1, Zone 2, etc. and indicate all zones having
either a Remote Room Sensor, or smart sensors associated with them. If the system
contains smart sensors, they must b e assigned a zone number before continuing.
See the Smart Sensor Installation Instructions on how to assign Smart Sensors to
their respective zones. After each zone has been identified, touch NEXT.