6.4.1. Electric Heat
If you have a fan coil with electric heaters, this menu item will allow the heaters to
be exercised. With self --identifying electric heaters, three stages of electric heat are
available to be exercised in any combination. Non --identifying heaters will only
provide one stage of heat; or perhaps may have fixed-- timed staging. See the
instructions provided with the electric heat accessory. After the selections are made,
touch START.
S Low Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
S Medium Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
S High Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
6.4.2. Furnace
Make sure the furnace is properly installed.
This option allows the furnace to be exercised. First, a low heat run time and high
heat run time are selected. The furnace will execute its ignition start--up sequence.
This sequence will be displayed on the screen. After the g as valve and blower
motor turn on, the screen will show the current operating status of the furnace. After
the selections are made, touch START.
S Low Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
S High Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes