With this option, the installer has the option of selecting pressure monitoring, the
type of filter installed, and the time interval for cleaning. After the selections are
made, touch SAVE.
S Pressure Monitoring (not available or effective with air cleaners that do not
use filter media, such as Electric Air Cleaners): Enable or Disable
d Default = Enab le
S Clean Interval: Selectable from 1 to 18 months
d Default = 3 months
S Filter Type: Air Filter, Electric Air Cleaner or Air Purifier
d Filter type is selected during installation; otherwise default = air filter
6.3.9.2. Humidifier
With this option, the installer has the option of selecting whether a humidifier is
installed, to humidify with the fan in low speed, and the time interval for changing
the humidifier pad. After the selections are made, touch SAVE.
S Humidifier Installed: Yes or No
d Humidifier selection made during installation; otherwise default = no
S Change Pad: Selectable from 1 to 24 months
d Default = 12 months
S Humidify with Fan: Yes o r No
d Default = No
6.3.9.3. Ultraviolet Lights
With this option, the installer has the option of selecting whether ultraviolet lights
are installed, and the time interval for changing the ultraviolet lights. After the
selections are made, touch SAVE.
S UV Lights Installed: Yes o r No
d UV Lights selection made during installation; otherwise default = no