Table 167 — Alarm Reference Lists
BY CODE
CODE ALARM NAME
Alarm 10001 Evaporator Freeze Protection
Alarm 10005 Circuit A Low Suction Temperature
Alarm 10006 Circuit B Low Suction Temperature
Alarm 10014 Customer Interlock failure
Alarm 10031 Unit is in Emergency Stop
Alarm 10032 Evaporator Pump #1 fault
Alarm 10033 Evaporator Pump #2 fault
Alarm 10037 Circ A - High Condensing temperature out of map compressor
Alarm 10038 Circ B - High Condensing temperature out of map compressor
Alarm 10067 Circuit A Low Oil Pressure
Alarm 10068 Circuit B Low Oil Pressure
Alarm 10070 Circuit A Max Oil Filter Differential Pressure
Alarm 10071 Circuit B Max Oil Filter Differential Pressure
Alarm 10075 Circuit A Low Oil Level
Alarm 10076 Circuit B Low Oil Level
Alarm 10078 Circuit A High Discharge Gas Temperature
Alarm 10079 Circuit B High Discharge Gas Temperature
Alarm 10081 Circuit A Suction Valve closed
Alarm 10082 Circuit B Suction Valve closed
Alarm 10084 Circuit A High Oil Filter Drop Pressure
Alarm 10085 Circuit B High Oil Filter Drop Pressure
Alarm 10091 Evaporator Flow Switch Failure
Alarm 10097 Water Exchanger Temperature Sensors Swap
Alarm 10101 Circ A - High saturated temperature out of map compressor
Alarm 10102 Circ B - High saturated temperature out of map compressor
Alarm 1101 Compressor A Motor temperature too high
Alarm 1103 Compressor A High Pressure Switch protection
Alarm 12001 Circuit A Discharge Transducer
Alarm 12002 Circuit B Discharge Transducer
Alarm 12004 Circuit A Suction Transducer
Alarm 12005 Circuit B Suction Transducer
Alarm 12010 Circuit A Oil Pressure Transducer
Alarm 12011 Circuit B Oil Pressure Transducer
Alarm 12013 Circuit A Economizer Pressure Transducer
Alarm 12014 Circuit B Economizer Pressure Transducer
Alarm 12031 Circuit A Condenser Subcooling Liquid Pressure Transducer
Alarm 12032 Circuit B Condenser Subcooling Liquid Pressure Transducer
Alarm 15001 Evaporator Entering Fluid Thermistor
Alarm 15002 Evaporator Leaving Fluid Thermistor
Alarm 15010 OAT Thermistor Failure
Alarm 15011 Dual Chiller Thermistor Failure
Alarm 15012 Circuit A Suction Gas Thermistor
Alarm 15013 Circuit B Suction Gas Thermistor
Alarm 15015 Circuit A Discharge Gas Thermistor
Alarm 15016 Circuit B Discharge Gas Thermistor
Alarm 15018 Circuit A Condenser Subcooling Liquid Thermistor
Alarm 15019 Circuit B Condenser Subcooling Liquid Thermistor
Alarm 15021 Space Temperature Thermistor
Alarm 15024 Circuit A Economizer Gas Thermistor
Alarm 15025 Circuit B Economizer Gas Thermistor
Alarm 15033 Circuit A Compressor Motor Thermistor
Alarm 15034 Circuit B Compressor Motor Thermistor
Alarm 17nnn Compressor VFD Error, Circuit A
Alarm 18nnn Compressor VFD Error, Circuit B
Alarm 20nnn Fan A1 VFD Error, Circuit A
Alarm 2101 Compressor B Motor temperature too high
Alarm 2103 Compressor B High Pressure Switch protection
Alarm 21nnn Fan A2 VFD Error, Circuit A
Alarm 23nnn Fan B1 VFD Error, Circuit B
Alarm 24nnn Fan B2 VFD Error, Circuit B
Alarm 35nnn Compressor VFD Error, Circuit A