Options No. Description Advantages
30RB/RBP
170R-950R
30RQ/RQP
165R-1040R
Compliance with
Australian regulations
200 Unit approved to Australian code Compliance with Australian regulations Standard 165R-1040R
Coil defrost
resistance heaters
252
Electric heaters under the coils and the
condensate pans
Prevents frost formation on the coils;
compulsory in heating mode if the outdoor
temperature is below 0 °C
No 165R-1040R
Insulation of the
evaporator inlet/
outlet refrigerant
lines
256
Thermal insulation of the evaporator inlet/
outlet refrigerant lines, with UV-resistant
exible connection and insulation
Prevents condensation on the evaporator
inlet/outlet refrigerant lines
170R-950R 165R-1040R
Enviro-Shield
anti-corrosion
protection
®
262
Coating applied using a conversion process
which modies the surface of the aluminium
producing a coating that is integral to the
coil. Complete immersion
in a bath to ensure 100% coverage.
No heat transfer variation, tested to
withstand more than 4000 hours of salt
spray as per ASTM B117
Improved corrosion resistance,
recommended for use in moderately
corrosive environments
170R-950R No
Anticorrosion coating
on Total Free Cooling
option coils
262AC
Same anticorrosion treatment as on
MCHE condenser coils
Improved corrosion resistance,
recommended for use in moderately
corrosive environments.
170R-950R No
Anticorrosion coating
on Partial Free
Cooling option coils
262BD
Same anticorrosion treatment as on
MCHE condenser coils
Improved corrosion resistance,
recommended for use in moderately
corrosive environments.
170R-950R No
Super Enviro-Shield
anti-corrosion
protection
®
263
Extremely durable and exible epoxy
polymer coating applied by electro coating
process, nal UV protective topcoat.
Minimal heat transfer variation, tested to
withstand more than 6000 hours of constant
neutral salt spray as per ASTM B117,
improved impact resistance as
per ASTM D2794
Improved corrosion resistance,
recommended for use in extremely
corrosive environments
170R-950R No
Welded evaporator
connection kit
266
Victaulic piping connections with welded
joints
Easy installation 170R-950R 165R-1040R
Flanged evaporator
water connection kit
268
Victaulic piping connections with anged
joints
Easy installation 170R-950R 165R-1040R
Compressor
enclosure
279a Compressor with enclosure
Improved aesthetics, compressor protection
against external elements (dust, sand,
water…)
170R-950R 165R-1040R
EMC class. C2, as
per EN 61800-3
282 Additional RFI lters on the unit power line
Reduces electromagnetic interference in
accordance with the emission level required
by category C2 to allow use in the rst
environment (“residential environment”)
170R-950R 165R-1040R
230 V electrical plug 284
230 VAC power source provided with plug
socket and transformer (180 VA, 0,8 A)
Enables connection of a laptop or an
electrical device during system start-up or
maintenance
170R-950R 165R-1040R
Expansion tank 293
6-bar expansion tank built into the hydraulic
module (requires hydraulic module option)
Easy and fast installation (plug & play),
& protection of closed water systems from
excessive pressure
170R-950R 165R-1040R
Electric energy meter 294
Electric energy meter. Display of energy
consumption, instantaneous (U, V, I)
and cumulative (kWh) on the machine
interface, data available on the
communication buses
Enables acquisition, monitoring (remote on
CMS/BMS) of energy used.
170R-950R 165R-1040R
Ultra-fast capacity
recovery
295+
Built-in capacity module to allow an
ultra-rapid restart whilst maintaining the
unit's reliability.
Full capacity recovery in less than 2.5
minutes after a power failure lasting less
than ten minutes. Matches requirements of
typical critical mission applications.
(process, data centres)
170R-950R No
Screwed water
connection sleeves
for desuperheater
303
DSH connections with screw connection
sleeves
Easy to install. Allows unit connection to
a screw connector
170R-950R 165R-1040R
12 - OPTIONS
67