ERROR AND STATUS CODES
6
5
For the following three tables, the indicator light mentioned in the rst
column is the green LED on the front cover, under the power switch.
Indicator Light Code Explanation Possible Cause Recommended Action
OFF
No incoming
AC power to air
purier control
electronics
Normal operation when airow is
not present for models without ow
sensor due to AC power to purier
being off at furnace control board
(EAC terminals)
ON/OFF power switch
turned to OFF
Turn purier power switch
to ON position
Power to entire system is off
(furnace and air purier)
Check that the HVAC system
is switched on
Blown fuse or tripped circuit
breaker for HVAC system
Replace fuse or reset circuit
breaker, call for service if
problem reoccurs
Misaligned or damaged
purier door
Insure that door is undamaged
and properly installed on
purier cabinet
Damaged or disconnected
incoming power wiring
Call for service
ON (continuously) Air purier on
Normal operation when
airow is present
Flashing
(one ash every
four seconds)
Standby mode
Normal operation when airow
is not present for models with
ow sensor
Ions detected in airow
due to missing replaceable
lter element
Place lter in air purier
Debris is covering airow sensor
(for models including an
airow sensor)
Make sure ow sensor is
clean and unobstructed
Flow sensor is damaged
(for models including an
airow sensor)
Replace ow sensor,
available as replacement kit
(KIT160000)
Flow sensor bypass assembly is
damaged (for models without an
airow sensor)
Replace ow sensor bypass
assembly, available as
replacement kit (KIT161000)
One or more of the three airow
sensor contact springs on purier
cabinet downstream rail are bent
of damaged
Replace ow sensor contact
spring assembly, included as part
of the ow sensor kits
(KIT160000) and ow sensor
bypass kit (KIT161000)
Table 1: Operating Status Codes
When the rapid ashing code occurs on the green light, the controls for the high voltage need to be reset.
To reset the controls, the power switch needs to be turned on and off for three cycles.
1. Turn off power by depressing the power switch.
2. Wait approximately two seconds before turning
the power back on.
3. Wait approximately two seconds before turning
the power off.
4. Repeat Steps 2 and 3 for two more on/off cycles.
5. After the three on/off cycles are completed, turn
on power by depressing the power switch on. The
rapid ashing code on the green light should no
longer be displayed. If the rapid ashing code on
the green light is still displayed, repeat Steps 1
through 5.
Note: By resetting the air purier controls the issue
with air purier will need to be addressed by
cleaning or servicing the air purier.
Reset Procedure