Do you have a question about the Carrier DHMSHAQ12XA3 and is the answer not in the manual?
Describes the process and equipment required for achieving a deep vacuum (500 microns) in the system.
Outlines the steps for performing a triple evacuation using dry nitrogen to ensure a contaminant-free system.
Warns about stored electrical charge in capacitors and provides instructions for safe discharge.
A table correlating operation lamp flashes, timer lamp states, display codes (E0-F5, P0-P4), and LED status with specific errors.
Details malfunction conditions, supposed causes, and troubleshooting steps for EEPROM parameter errors.
Covers malfunction conditions, causes, and troubleshooting for indoor/outdoor unit communication errors.
Details malfunction conditions, causes, and troubleshooting for zero crossing detection errors.
Covers malfunction conditions, causes, and troubleshooting steps for indoor fan speed control issues.
Details malfunction conditions, causes, and troubleshooting for open circuit or short circuit of temperature sensors.
Covers malfunction conditions, causes, and troubleshooting for refrigerant leakage detection errors.
Details malfunction conditions, causes, and troubleshooting steps for overload current protection.
Covers malfunction conditions, causes, and troubleshooting for IPM malfunction or over-strong current protection.
Details malfunction conditions, causes, and troubleshooting for over voltage or low voltage protection.
Covers malfunction conditions, causes, and troubleshooting for compressor high temperature protection.
Details malfunction conditions, causes, and troubleshooting for inverter compressor drive errors.
Describes the process and equipment required for achieving a deep vacuum (500 microns) in the system.
Outlines the steps for performing a triple evacuation using dry nitrogen to ensure a contaminant-free system.
Warns about stored electrical charge in capacitors and provides instructions for safe discharge.
A table correlating operation lamp flashes, timer lamp states, display codes (E0-F5, P0-P4), and LED status with specific errors.
Details malfunction conditions, supposed causes, and troubleshooting steps for EEPROM parameter errors.
Covers malfunction conditions, causes, and troubleshooting for indoor/outdoor unit communication errors.
Details malfunction conditions, causes, and troubleshooting for zero crossing detection errors.
Covers malfunction conditions, causes, and troubleshooting steps for indoor fan speed control issues.
Details malfunction conditions, causes, and troubleshooting for open circuit or short circuit of temperature sensors.
Covers malfunction conditions, causes, and troubleshooting for refrigerant leakage detection errors.
Details malfunction conditions, causes, and troubleshooting steps for overload current protection.
Covers malfunction conditions, causes, and troubleshooting for IPM malfunction or over-strong current protection.
Details malfunction conditions, causes, and troubleshooting for over voltage or low voltage protection.
Covers malfunction conditions, causes, and troubleshooting for compressor high temperature protection.
Details malfunction conditions, causes, and troubleshooting for inverter compressor drive errors.
| Model | DHMSHAQ12XA3 |
|---|---|
| Cooling Capacity | 12000 BTU/h |
| Cooling Capacity (Ton) | 1 Ton |
| Refrigerant | R-410A |
| Voltage | 208/230 V |
| Smart Control | Yes |
| Air Flow (High) | 350 CFM |
| Net Weight (Outdoor Unit) | 35 kg |
| Power Supply | 60 Hz |
| Type | Mini Split Air Conditioner |