EasyManua.ls Logo

Carrier GAPAA - Installation

Carrier GAPAA
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
INSTALLATION
Check Infinity Air Purifier Components
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.
CAUTION
!
Carefully remove all items from the box.
Identify Mounting Location
a. Identify a mounting orientation for the Infinity Air Purifier
in the return air duct (see Figures 3 and 4).
IMPORTANT:
b. Ensure airflow direction through the Infinity Air Purifi-
er matches the arrows on the face of the air purifier
cartridge and those on the sticker inside the cabinet. The
Infinity Air Purifier can be rotated 180_ to accommo-
date the cabinet orientation.
c. The location of the Infinity Air Purifier should be readily
accessible. Enough room should be provided for periodic
replacement of the air purifier cartridges.
ELECTRIC SHOCK AND UNIT DAMAGE HAZARD
Failure to follow this warning could result in personal injury
or death.
Only a trained, experienced service person should install the
Infinity Air Purifier. A thorough check of the unit installation
should be completed before unit operation. Before performing
installation, service or maintenance operations on unit, turn off
all power to unit. Tag disconnect switch with lockout tag.
!
WARNING
Airow
Airow
Airow
Upow Furnace with Side Return
Horizontal Application
Upow Furnace with Bottom Mount Downow Furnace with Top Mount
Airow
NOTE:
Mounting on this side
requires the cabinet
to be rotated 180° for
correct air ow.
A06028
Fig. 3 -- Infinity Air Purifier Cabinet Orientation
GAPAA

Related product manuals