1-10
T--295
b. Thermal Circuit Breakers
CB 1 Evaporator Fan #1. 15 Amp.
CB 2 Evaporator Fan #2. 15 Amp.
CB 3 Evaporator Fan #3. 15 Amp.
CB 4 Evaporator Fan #4. 15 Amp.
CB 5 Evaporator Fan #5. 15 Amp.
CB 6 Evaporator Fan #6. 15 Amp.
CB 7 Condenser Fan #1. 15 Amp.
CB 8 Condenser Fan #2. 15 Amp.
CB 9 Condenser Fan #3. 15 Amp.
CB10 Condenser Fan #4. 15 Amp.
CB11 Condenser Fan #5. 15 Amp.
CB12 Condenser Fan #6. 15 Amp.
CB13 A/C clutch, Unloaders 1&2,
Fresh Air Damper , Heat Valve,
Fault Output and Spare
output. 15 Amp
c. Connectors
EF1-EF6 Evaporator fans.
CF1-CF4 Condenser fans.
JP1 External evaporator & condenser fan
thermal overload connections.
JP2 Logic board connector .
JP3 Boost pump.
JP4 A/C clutch, fault output, compressor high
pressure switch.
JP5 Spare output, fresh air output, heat valve.
JP6 Unloaders 1 & 2.
d. LEDS
D 2 Relay K1 output active (evaporator fans 1,2,3 &
4 energized)
D 6 Will be brightly lit if evaporator fans 1, 2, 3 & 4
are on high. Will be at half intensity of they are on low.
D14 Relay K3 output active (evaporator fans 5 & 6
energized).
D17 .Will be brightly lit if evaporator fans 5 &6 are
on high. Will be at half intensity of they are on low.
D26 Relay K7 output active (condenser fans 1, 2, 3
& 4 energized).
D30 Will be brightly lit if condenser fans 1, 2, 3 & 4
are on high. Will be at half intensity of they are on low.
D38 Relay K9 output active (condenser fans 5 & 6
energized).
D41 Will be brightly lit if condenser fans 5 &6 are on
high. Will be at half intensity of they are on low.
D51 A/C clutch output active.
D54 Unloader 1 output active.
D57 Unloader 2 output active.
D60 Fresh air output active.
D63 Heat valve output active.
D66 Fault output active.
D69 Boost pump output active.
D72 Spare output active.