2
MODEL NUMBER NOMENCLATURE
12 3 4 5 6 78 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
25 H N B 6 36 A 0 0 3 0
Product
Series
Product
Family
Tier
Major
Series
SEER
Cooling
Capacity
Variations Open Open Voltage
Minor
Series
25=HP H=RESHP
N=
Infinity Series
B = Puron 6=16 SEER
1,000 Btuh
(nominal)
A=Standard
0=Not
Defined
0=Not
Defined
3=208/230---1 0, 1, 2...
the environmentally sound refrigerant
This product has been designed and manufactured to
meet Energy Star® criteria for energy effici ency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
This product has been designed and manufactured to
meet Energy Star® criteria for energy effici ency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
STANDARD FEATURES
FEATURES
Unit Size --- Voltage, Series
24---30 36---30 48---30 60 ---30
Puron Refrigerant X X X X
Maximum SEER Rating* 16.5 17.2 16.4 15.8
2---Stage Scroll Compressor X X X X
Louvered Coil Guard X X X X
FieldInstalledFilterDrier X X X X
Front Seating Service Valves X X X X
Internal Pressure Relief Valve X X X X
Long Line capability X X X X
Loss of Charge Switch X X X X
High Pressure Switch X X X X
Crankcase Heater X X X X
Low ambient cooling down to 0_F capability
with Infinity Control
X X X X
Utility Interface Connect ions X X X X
Enhanced Diagnostics with Infinity Control X X X X
Sound Blanket X X X X
X=Standard
* With approved combinations