3
PHYSICAL DATA
UNIT SIZE SERIES 24--- 30 36--- 30 48 ---30 60--- 30
Operating Weight lb (kg) 314 (142) 316 (143) 316 ( 143) 372 (169)
Shipping Weight lb (kg) 358 (162) 360 (163) 360 ( 163) 417 (189)
Compressor Ty pe Ultratechr Scroll
REFRIGERANT Puron® ( R ---410A)
Control TXV (Puron ® Hard Shutoff)
Charge lb (kg) 14.0 (6.35) 14.10 (6.40) 14.25 (6.46) 15.45 (7.01)
Outdoor Htg Piston # 46 57 61 67
COND FAN Forward Swept Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 3200 3900 4350 5000
Motor HP 1/12 1/8 1/4 1/4
Motor RPM 800 800 800 800
COND COIL
Face Area (Sq ft) 25.15 25.15 25.15 30.18
Fins per In. 20 20 20 20
Rows 2 2 2 2
Circuits 8 8 8 10
VALVECONNECT.(In.ID)
Vapor 3/4 7/8 7/8 7/8
Liquid 3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor* 3/4 7/8 1 --- 1 / 8 1 --- 1 / 8
Max Liquid Line 3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Unit
Nominal
Size
(Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In.) OD
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
Long Line Application Requires Accessories
26--- 50
(7.9---15.2)
51--- 80
(15.5---24.4)
81--- 100
(24.7---30.5)
101--- 125
(30.8---38.1)
126--- 150
(38.4---45.7)
151--- 175
(46.0---50.3)
176--- 200
(53.6---60.0)
201--- 225
(61.3---68.6)
226--- 250
(68.9---76.2)
24,000
2 --- S t a g e
HP with
Puron
3/8
5/8 0 1 1 2 3 3 4 4 5
3/4 0 1 1 1 1 1 1 1 1
36,000
2 --- S t a g e
HP with
Puron
3/8
5/8 1 2 4 5 6 7 9 10 11
3/4 0 0 1 1 2 2 3 3 4
7/8 0 0 — — — — — — —
48,000
2 --- S t a g e
HP with
Puron
3/8
3/4 1 2 2 3 4 5 6 7 7
7/8 0 1 1 2 2 2 3 3 4
1 --- 1 / 8 0 0 — — — — — — —
60,000
2 --- S t a g e
HP with
Puron
3/8
3/4 1 2 4 5 6 8 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 --- 1 / 8 0 0 — — — — — — —
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit.
— Applications in this area are not recommended due to insuficient oil return.