80
Equipment Control Module
Furnace Heat Pump
O
RVS Cooling O/B W2 W2
W2**
Heat Stage 3
(furnace)
Y1 / W2 W/W1
Heat Stage 2
(furnace)
W/W1 Y1
Heat/Cool Stage 1 Y/Y2 Y/Y2 Y
Fan G G
24VAC Hot Heating Rh R R
24VAC Hot Cooling Rc
Dry Contact 1 D1
Dry Contact 2 D2 DHUM
24VAC Common C
COM
C
Humidify HUM
Outdoor Air Temp OAT
Remote Room Sensor RRS
OAT/RRS Com SRTN
Outdoor Sensor *
Humidifier Solenoid
Valve *
Remote Room
Sensor *
***
* Indicates connection may not be required/available.
** Some heat pumps may designate W1.
***Option 19 set to 2.
A09125
Fig. 35 -- Variable Speed, Multi--Stage and Step Modulating Furnace with
Single--Stage Heat Pump