MENU
Menu tree structure
Legend
* Displayed if the configuration requires it
** Displayed if the alarm exists
- Not in use
ITEM
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
STATUS
Default display
Mode
Chiller occupied/
unoccupied
mode*
Minutes left
Cooling/heating
selection*
Cooling/heating
status*
Heat reclaim
selection*
Heat reclaim
status
Unit capacity in
%
Capacity circuit
A in %*
Capacity circuit
B in %*
Present demand
limit in %
Present lag limit
in %*
Setpoint in local
control*
Setpoint occu-
pied/unoccupied
mode*
Active setpoint
Control point
Controlled water
temperature
TEMP
Evaporator water
entering temp.
Evaporator water
leaving temp.
Condenser water
entering temp.
Condenser water
leaving temp.
Outdoor tempera-
ture
Saturated discharge
temperature, circ. A
Saturated suction
temp. circuit A
Saturated discharge
temperature circuit
B*
Saturated suction
temp. circuit B*
Drycooler leaving
water temperature*
System water
temperature*
-
-
-
-
-
-
-
PRESSURES
Discharge pressure
circuit A
Suction pressure
circuit A
Discharge pressure
circuit B*
Suction pressure
circuit B*
-
-
-
-
-
-
-
-
-
-
-
-
-
SETPOINTS
Cooling setpoint 1
Cooling setpoint 2
Heating setpoint 1*
Heating setpoint 2*
Heating setpoint 3*
Setpoint demand
limitation 1*
Setpoint demand
limitation 2*
Setpoint demand
limitation 3*
Ramp loading*
Cooling - zero reset
threshold*
Cooling - full reset
threshold*
Cooling - full reset
value*
Heating - zero reset
threshold*
Heating - full reset
threshold*
Heating - full reset
value*
-
-
-
INPUTS
Contact 1: on/off
Contact 2: heating/
cooling or heat
reclaim
Contact 3: demand
limit/setpoint
selection
Contact 4: demand
limit selection*
Contact 5: setpoint
selection*
Contact 6: setpoint
selection*
Safety loop status
Evaporator water
pump operation
contact status*
Condenser water
pump operation
contact status*
Fault contact, com-
pressor, circuit A
Fault contact, com-
pressor, circuit B*
-
-
-
-
-
-
-
OUTPUTS
Compressor status
circuit A
Compressor status
circuit B*
Fan status, unit
without condenser,
circuit A
Fan status, unit
without condenser,
circuit B*
Fan status,
drycooler
Evaporator water
pump 1 status*
Evaporator water
pump 2 status*
Condenser water
pump 1 status*
Condenser water
pump 2 status*
Speed condenser
pump 1*
Speed condenser
pump 2*
Alarm circuits A and
B status
Boiler status*
Speed, fan A in %*
Speed, fan B in %*
Solenoid valve
status
User interface test
-
CONFIG
SUB-MENU: User
Configuration (USEr)
SUB-MENU:
Service Configuration
(SErviCE)
SUB-MENU:
Factory Configuration
(FACtorY)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ALARMS
Number of active
alarms/resets**
Active alarm code 1**
Active alarm code 2**
Active alarm code 3**
Active alarm code 4**
Active alarm code 5**
-
-
-
-
-
-
-
-
-
-
-
-
ALARMS HIST
Historic alarm code
1**
Historic alarm code
2**
Historic alarm
code 3**
Historic alarm code
4**
Historic alarm code
5**
Historic alarm code
6**
Historic alarm code
7**
Historic alarm code
8**
Historic alarm code
9**
Historic alarm code
10**
-
-
-
-
-
-
-
-
RUNTIMES
SUB-MENU:
Runtimes 1
SUB-MENU:
Runtimes 2
SUB-MENU:
Maintenance
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Note:
The items in brackets show what is displayed on the user interface