Carrier Transicold Europe 31/03/07 Viento - Installation/Rev- #17/54
4. Measure the roof thickness.
5. Adjust the mushroom length (L) to the roof thickness
minus the internal skin thickness (E –E')
L: mushroom length
E: roof thickness
E': internal skin thickness
Mushroom in place
1. mushroom
2. silicon gasket
3. skin of external box
4. polyurethane foam
5. skin of internal box
6. evaporator upper side
7. washer
8. screw M12
Installation Box preparation Mushrooms Preparation