3
FEATURES AND BENEFITS
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S 3 -- 10 ton units fit on existing Carrier rooftop curbs which saves time and money on replacement jobs.
S Standardized components and layout. Standardized components and controls make service and stocking parts easier.
S Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier.
S Crankcase heater on all models (except 04 size) provides added protection in all applications.
S Precision--sized refrigerant suction line accumulator provides high reliability by preventing liquid from entering the
compressor during low ambient conditions and reverse cycle switch over.
S Filed convertible from vertical to horizontal airflow on all models. No special kits required on 04--09 models. Supply
duct kit required for 12 size model only.
S 4--way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating
to cooling.
S Easy--adjust, belt drive motor available on all sizes. Carrier provides a factory solution for most points in the fan
performance table. There’s no need for field--supplied drives or motors.
S 3--5 ton models come standard with an Electric Drive X13, 5 speed/torque motor to provide exact performance in many
applications. Belt drive motor optional on all three phase voltage models.
S Provisions for bottom or side condensate drain.
S Capable of thru--the--base or thru--the--curb electrical routing.
S Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is
adjustable.
S Single--point electrical connection.
S Sloped, composite drain pan sheds water; and won’t rust.
S Standardized controls and control box layout. Standardized components and controls make stocking parts and service
easier.
S Clean, easy to use control box.
S Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design.
S Color--coded wiring.
S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
S Single, central terminal board for test and wiring connections.
S Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
S “No--strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or
the unit.
S Exclusive, newly--designed indoor refrigerant header for easier maintenance and replacement.
S Standard mechanical cooling (125_Fto30_For52_Cto--1_C) .
S 2--in. (51mm) disposable filters on all units.
S High capacity refrigerant filter drier and TXV metering device on each circuit.
S High pressure switch, loss of charge switch and freeze protection adds greater unit reliability.