11
10
SPECIFICATIONS
ERROR MESSAGE
Failure of A/D Module
An error of initial zero range
Call your CAS dealer
Set the platter empty
Make sure there is a platter on the scale
ERROR REASONS SOLUTIONS
Err
Err 1
Most POS, ECRs and Some
TEC POS System
Sharp ER-Axxx, New Sanyo
ECRs using RS-232 others
Most POS System
Samsung, CRS, NCR2170 and
other ECRs
NCI General.
Most POS Software
Samsung ER-670
TEC 4 Digit 4Bit Parallel
(New kg)
TEC 4 Digit 4Bit Parallel
(Old kg)
Universal 4 Bit Parallel
ECR-TYPE 0
ECR-TYPE 1
ECR-TYPE 2
ECR-TYPE 3
ECR-TYPE 4
ECR-TYPE 5
ECR-TYPE 6
key
4-Bit Parallel
RS-232 Serial
Serial Communication
9600 Baud Rate, 7 Date bit, Even Parity. 1 Stop bit
Table 1.
MODEL
DIVISION
INTERNAL RESOLUTION
EXTERNAL RESOLUTION
DISPLAY
DISPLAY LAMP
INTERFACE
PRODUCT SIZE
PLATTER SIZE
PRODUCT WEIGHT
TEMPERATURE RANGE
POWER SUPPLY
15 lb 30 lb 60 lb 150 lb
6 lb 0.002 lb 15 lb 0.005 lb 30 lb 0.01lb 60 lb 0.02 lb
15 lb
0.005 lb 30 lb 0.01 lb 60 lb 0.02 lb 150 lb 0.05 lb
1/90,000
1/3,000 DUAL
VFD 6 DIGITS
ST(STABLE), ZERO
RS-232C, 4-Bit Parallel Communication (ECR Interface)
380(W)
280(D) 79(H) [mm]
380(W)
280(D) [mm]
6.7kg
10°C 40°C
AC 120V /60Hz
DUAL INTERVAL