71
x M : number of sales in receipt
N : number of digit(s)
M : constant digit(s)
The parameter X specifies what will be printed. You can choose between several
parameters and can set how many digits will be printed.
The parameter N after parameter X is a obligatory! It give the number of digits which
will be printed from value specified with parameter X.
The constant digits M is not obligatory, they can be insert anywhere in the string
between group XN and will be print unconditionally.
The total number of digits in the barcode after interpretation must be stay exactly :
x 12 digits for EAN13 (1 digits by itself),
x 11 digits for UPCA (1 digits by itself),
x 7 digits for EAN8 (1 digits by itself),
x CODE128 have variable number of digits max 26. (For this barcode are
accepted only even number of digits. Max Constant digits = 12digits)
If is set U, N or D type to total barcode then these values will be take from last sale!
If is set M for barcode for a single sale then value will be number of current sale.
Case 1 (EAN13 type) :
Assumption:
x Weight -1.025
x Unit price - 2.28
x String- (total is 12 digits input)Then,
Barcode -> 1 01025 1 00228 (total is 12 digits input)