12
CAS ELECTRICS CO.,LTD
For exampe,
DIGIT 6
DIGIT 5
DIGIT 4
DIGIT 3-2
DIGIT 1
2
0
0
10
0
Decimal 2
Vibration
filter
Disable
Weight unit
=> kg
30 kg
Single
1/3000
Unit price
weight unit
=> kg
Parameter setting, see below table.
DIGIT
Description
Value
Description
DIGIT 6
Unit price
Decinal point
0-3
0: use decimal 0
1: use decimal 1
2: use decimal 2
3: use decimal 3
DIGIT 5
Vibration Filter
0~1
0: Disable
1: Enable
DIGIT 4
Weight unit
0~1
0: kg
1: lb
DIGIT 3-2
Capacity setting
00~14
Refer to capacity table
DIGIT 1
Unit price
weight unit
0
kg (or lb)
1
100 g (or oz)
Capacity table
Setting
Value
Mode
Interval
e (g)
Resolution
00
6 kg
dual
1/2
1/3000
01
6 kg
single
2
1/3000
02
6 kg
single
1
1/6000
03
6 kg
single
0.5
1/12000
04
6 kg
single
0.2
1/30000
05
15 kg
dual
2/5
1/3000
06
15 kg
single
5
1/3000
07
15 kg
single
2
1/7500
08
15 kg
single
1
1/15000
09
15 kg
single
0.5
1/30000
10
30 kg
dual
5/10
1/3000
11
30 kg
single
10
1/3000
12
30 kg
single
5
1/6000

Other manuals for CAS PR-II Series