SECTION 2 - CONTROLS, INSTRUMENTS AND OPERATION
2ï111
Memory fault
Should a memory fault appear it may be necessary to
reload the software.
Still have memory fault change the monitor.
Pick-up cut out Auto Stop function (where fitted on
Rotor-Cutter balers only)
The auto pick-up cut out operates should the stuffer
shear bolt fail and limits the crop entering the pre
charge chamber. When the pick-up fails its sensor
activates the pick-up stop valve. Density pressure is
dumped into the stop cylinder and a pawl locks the
pick-up drive sprocket making the drive slip clutch slip
there by stopping the pick-up.
IMPORTANT: The tractor PTO must be shut down
immediately.
A shearbolt warning message will appear and the
baler will stop.
The pick-up stop valve is deactivated when the baler
drops below < 600 rpm.
NOTE: This function can only be installed or not installed
in the machine set up mode by the Dealer.