Chapter 3: Commands and Programming
4 Channel 4 (SONIC)
5 DIG IN channel
Operation Parameter
This parameter specifies the sampling unit for the Multimeter Mode.
The following are the available operation parameter settings whenever Channel
1 (CH1), Channel 2 (CH2), or Channel 3 (CH3) is specified by the channel
select parameter.
1 Auto-ID
If Auto-ID is not activated, voltage in the range 0 to 5V is used.
2 Voltage (±10V)
3 Current (±10A)
4 Resistance value (1k% to 100k%)
5 Period (0.000004 to 50 seconds)
6 Frequency (0.02Hz to 250kHz)
The following are the available operation parameter settings whenever SONIC
is specified by the channel select parameter.
1 Auto-ID
2 Meters
3 Feet
MULTIMETER MODE SETUP Example
The following example takes a single data sample on Channel 1.
{6,1,1,3} 6 = MULTIMETER MODE SETUP
1 = Enters Multimeter Mode
1 = Channel 1
3 = Current measurement