5-3. Low voltage monitoring
Therearefourlowvoltagedetectionlevelsonthehardwareofthedevice.
Level Content Operation Action on next start-up
VDET1 Warning on voltage reduction of
mainbattery
Display of warning on
voltage reduction of main
battery
―――――
VDET2 Power OFF due to voltage
reductionofmainbattery
PowerOFF Resume (with warning
messageonstart-up)
VDET3 Emergency power OFF due to
voltagereductionofmainbattery
CriticalpowerOFF Warm boot (with warning
messageonstart-up)
VDETPC Power OFF due to PC voltage
reduction
PowerOFF Resume (with warning
messageonstart-up)
Voltagemonitoringofthemainbattery
English indication Details
Status External Externalpowersource The power is supplied from an external power source
andchargingiscompleted.
Charge Batteryisundercharging The power is supplied from an external power source
andchargingisinprogress.
Normal Mainbattery Thedeviceisbatteryoperated.
Level 1 O.K. Thebatteryis fully charged orthe remaining power of
thebatteryissufcientforoperationofthedevice.
2 Low Theremainingpowerofthebatteryishalforless.
3 Verylow WhenVDET1isdetected.
<Thestatusandthelevelofthemainbattery>
Thebatterystatusisusuallycheckedata5-secondinterval.
OnlyduringthepropertyofPowerManagementisdisplayed,thebatterystatusischeckedata1-second
interval.
Calculatetheaverageoftheprevious10dataontheADconverterforthepowersupplyvoltage,categorize
thevaluesinto"Verylow(10%)","Low(25%)",and"O.K.(75%,100%)"anddisplayintext.Occurrenceof
VDET1means10%.