— 53 —
[ 22 ] OBR (Scanner) test
This test will check the OBR function. The test checks the fixed data and read data comparison.
The fixed data is "49400250".
Scanner cable connects to COM2 before this test.
Operation : 9 5 SUBTOTAL
Note : To stop the test, press "Esc" key.
( 1 ) When the read data is correct.
( 2 ) When the read data is incorrect, bar code will be displayed.
KEY 94
KEY#mmm
END 94
[ LCD ]
#mmm = =Key code
OBR 95
OBR OK
OBR ERR *******************
ESC
END 95
[ PRINT ][ LCD ]
OBR 95
OBR OK
OBR ERR *******************
ESC
END 95
(1)
(2)
[ 21 ] Key display test
The display shows pressed button number when the key switch function correctly.
Operation : 9 4 SUBTOTAL
Note : To stop the test, press "Esc" key.
[ LOCATION OF THE KEY CODE ]
14 28 42 56 70 84 98 112 126 140 154 168
13 27 41 55 69 83 97 111 125 139 153 167
12 26 40 54 68 82 96 110 124 138 152 166
11 25 39 53 67 81 95 109 123 137 151 165
10 24 38 52 66 80 94 108 122 136 150 164
9 23 37 51 65 79 93 107 121 135 149 163
8 22 36 50 64 78 92 106 120 134 148 162
7 21 35 49 63 77 91 105 119 133 147 161
6 20 34 48 62 76 90 104 118 132 146 160
5 19 33 47 61 75 89 103 117 131 145 159
4 18 32 46 60 74 88 102 116 130 144 158
3 17 31 45 59 73 87 101 115 129 143 157
2 16 30 44 58 72 86 100 114 128 142 156
1 15 29 43 57 71 85 99 113 127 141 155
C (ESC)